Neon Soft X-Ray Yield Optimization from NX2 Dense Plasma Focus Device

Authors

  • Walid Sahyouni
  • Alaa Nassif

Abstract

The aim of this research is to study soft x-ray emission from NX2 plasma focus device with neon filling gas using the Lee model code and find the maximum value of soft x-ray yield by using the standard parameters of the device and then find the optimum combination of pressure and anode dimensions that gives the maximum value of soft x-ray yield. Many numerical experiments were carried out and we obtained the maximum value of soft x-ray yield (Ysxr) of (22.6 J) at a pressure of (2.9 Torr) by using the standard parameters of NX2 device. We found the optimum combination of pressure, anode length and anode radius (3 Torr, 2.1 cm and 2 cm), respectively, by reducing the anode length and increasing the anode radius. The soft x-ray yield increases to (26.01 J) with a corresponding efficiency of about 1.53%.

Keywords: Lee model code, NX2 device, Soft x-ray yield

Downloads

Published

2025-04-24

How to Cite

Walid Sahyouni, & Alaa Nassif. (2025). Neon Soft X-Ray Yield Optimization from NX2 Dense Plasma Focus Device. Jordan Journal of Physics, 11(3). Retrieved from https://jjp.yu.edu.jo/index.php/jjp/article/view/802