The aim of this research is to study soft x-ray emission from NX2 plasma focus device with neon filling gas using the Lee model code and find the maximum value of soft x-ray yield by using the standard parameters of the device and then find the optimum combination of pressure and anode dimensions that gives the maximum value of soft x-ray yield. Many numerical experiments were carried out and we obtained the maximum value of soft x-ray yield (Ysxr) of (22.6 J) at a pressure of (2.9 Torr) by using the standard parameters of NX2 device. We found the optimum combination of pressure, anode length and anode radius (3 Torr, 2.1 cm and 2 cm), respectively, by reducing the anode length and increasing the anode radius. The soft x-ray yield increases to (26.01 J) with a corresponding efficiency of about 1.53%.