Thermoluminescence Dosimetry Measurement of Ionizing Radiation at the Radio Diagnostic Center, National Orthopaedic Hospital Igbobi, Lagos, Nigeria
Abstract
Abstract: Ionizing radiation measurement and monitoring are very important and pose an increasing international concern. In this study, the level of exposure to ionizing radiation among radiation health workers and outdoor patients at the Radio Diagnostic Center of the National Orthopedic Hospital Igbobi, Lagos State, Nigeria was determined. Thermoluminescence dosimeters (TLDs) made from Lithium Fluoride were deployed at ten strategic locations within and around the X-ray facilities over a 41-day period to measure effective radiation doses received by health workers and the general public. In the X-ray rooms, mean annual effective doses (mSv) of 39.52, 2.05, 1.25 and 1.16 were detected at the Trauma X-ray unit, main X-ray unit and modular theatres 1 and 2, respectively. Outside the X-ray rooms, the mean effective doses were significantly lower, indicating good containment of radiation emitted from the X-ray machines. The study confirms that while some occupational zones exceed recommended limits under continuous exposure, standard operational protocols (e.g., avoiding presence in the room during exposure) and proper shielding effectively protect both workers and the public from harmful radiation levels.
Keywords: Radio-diagnosis, Thermoluminescence, Dosimeter, Effective dose, Ionizing Radiation.
References
Agba, E.H and Abu, G. (2005). Radiation Exposure for Common Diagnostic Procedures. Journal of Interdisciplinary Studies, Benue State University 4: 80-88
UNSCEAR (2020/2021). United Nations Scientific Committee on the Effects of Atomic Radiation. Sources, Effects and Risks of Ionizing Radiation. Volume 1 Scientific Annex: Evaluation of Medical Exposure from Ionizing Radiation.
NCRP (2019). The National Council on Radiation Protection and Measurements (NCRP) Report No. 184: Medical Radiation Exposure of Patients in the United States.
Ogundare, F. O., & Adekoya, O. I. (2015). Gross Alpha and Beta Radioactivity Journal of Radiation Research and Applied Science, 8, 411-417. https://doi.org/10.1016/j.jrras. 2015.02.009
Aschan, C. (1999). Applicability of Thermoluminescence dosimeters in x-ray organ dose determination and the dosimetry of systematic and boron neutron capture radiotherapy. Academic Dissertation, Department of Physics, University of Helsinki, Finland.
Bhatt, B.C., and M.S. Kulkarni. 2014. Thermoluminescent phosphors for radiation dosimetry. Chapter in Defect and Diffusion Forum 347: 179-227.
Rizk, C., S. Long, H.B. Okyar, S. Baradaran, E.Al Fares, J.K. Sangau, and B. R. Shah. 2019. Results of the Joint IAEA/ARPANSA Intercomparison Exercise on Whole Body Dosemeters for Photons in Asia and the Pacific Region. Radiation Protection Dosimetry, 182:1-8.
Blackman, T. E., Johns, T. F. Preston, H. E. Mason, E. W., Marshall, T. O. & Shaw, K. B. (1974), Correct handling of thermoluminescent LiF: Teflon dosimeters, British Journal of Radiology, 47 (558): 361, https://doi.org/10.1259/0007-1285-47-558-361-b
Campos, L.L. & Fernandes Filho, O.O (1990). Thermoluminescent Characterisation of MgB4O7:Dy Sintered Pellets, Radiation Protection Dosimetry, 33(1-4):111–113, https://doi.org/10.1093/rpd/33.1-4.111
Sharma R. (2015) Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system. Journal of Medical Physics 40(1):29-37
Hassan G.M., Rabie N., Mustafa K.A. & Abdel-Khalik S.S. (2012) Study on the quality assurance of diagnostic X-ray machines and assessment of the absorbed dose to patients, Radiation Effects and Defects in Solids, 167:9, 704 711, doi.org/ 10.1080/10420150.2011.5 59238
Eshiet P., Dlama J., Tom A., Musa G., Kpaku G., & Mundi A (2016). Assessment of Radiation Protection Measures in a Nigerian Tertiary Health Care Center. Journal of Health, Medicine and Nursing. 31:90-104
ICRP (2007). The 2007 Recommendations of the International Commission on Radiological Protection, ICRP Publication 103. Ann. ICRP 37 (2-4)